Software API-PAC(W32) ACX-PAC(W32)BP,ACX-PAC(W32)AP IO-LIB(LNX)
Accessories (option) Solderless relay terminal
unit: EPD-37 *1 Terminal unit for solderless terminal (M3)
: DTP-3(PC) Lead terminal unit :
DTP-4(PC) Signal monitor accessories for digital I/O: CM-32(PC)E *1 *1
Option cable PCB37P or PCB37PS is required separately
Cable (option)
PCB37P-* (1.5m, 3m, 5m) PCB37PS-*P (0.5m, 1.5m, 3m, 5m) PCA37P-* (1.5m, 3m, 5m) PCA37PS-*P (0.5m, 1.5m, 3m, 5m)
|
- In order for 16-point unit to carry out common composition, it can common
every respond to a different external power supply.
- Since the PCI bus (personal computer) and the I/O interface are insulated by
the photo-coupler, it excels in noise-proof nature.
- All the input signals can be used as an interruption input.
Moreover,
the edge of the input signal which generates interruption can also be chosen.
- It has the digital filter function for preventing the incorrect input by the
noise or the chattering.
- The rating of an output signal is a maximum of 35VDC and 100mA per point.
- Zener diode is connected to the output transistor for protection from serge
voltage. Moreover, the over-current protection element is attached per eight
output transistors.
- PIO-16/16L(PCI)H, and PIO-16/16L(PCI) are connector pin compatibles.
|